Every count, map colour and table on this site comes from one public file and one set of rules. This page describes both, so that anyone can check a figure against the source.
The data
The source is the EPA's final data from the fifth Unregulated Contaminant Monitoring Rule (UCMR 5), downloaded from the EPA's UCMR occurrence data page. We use the file of all analytical results (UCMR5_All.txt, dated 15 October 2026 in the EPA's download), which holds 1,991,977 results from 10,313 public water systems, for 29 PFAS and lithium, with samples collected between January 2023 and June 2026. The list of ZIP codes each system serves comes from the file UCMR5_ZIPCodes.txt in the same download. The EPA's own summary of this data is “UCMR 5 Data Summary: July 2026” (EPA 815-S-26-007), included in the same download.
UCMR 5 tested every community and non-transient non-community water system serving 3,300 or more people, and a nationally representative sample of smaller ones. It did not test private wells. All samples were taken at entry points, where treated water enters the distribution system.
The rules, which are the EPA's own
To compare UCMR 5 results with the drinking water limits set in April 2024, we follow the rules the EPA describes in Table 4 of its data summary and its footnotes:
- A result reported as below the minimum reporting level counts as zero. For PFOA and PFOS that level is 4 ppt.
- A sampling location counts only if it has a full set of results: two for locations supplied by ground water, four for locations supplied by surface water.
- For each location we take the average of its results for each PFAS.
- A location is above the 4.0 ppt limit for PFOA or PFOS if its average is 4.05 ppt or more, because the limit is written with two significant digits. For PFHxS, PFNA and HFPO-DA (limit 10 ppt, one significant digit) the cut-off is 15 ppt.
- A water system counts as above a limit if at least one of its locations is.
One part ppt (part per trillion) is one nanogram per litre. The EPA file gives results in micrograms per litre; we multiply by 1,000.
Checking our counts against the EPA's
Applied to the file, these rules reproduce the EPA's Table 4. For large systems (serving more than 10,000 people) we count 472 above the PFOA limit and 524 above the PFOS limit, against the EPA's 472 and 523; for all other systems we count 307 and 352, exactly as the EPA does. For systems above at least one of the 2024 limits, we count 662 large systems, as the EPA does, and 476 others, against the EPA's 474. We also find 3,595 systems with at least one PFAS detected at or above its reporting level, the same number as the EPA's Table 5.
The one measure we do not reproduce exactly is the Hazard Index for mixtures of PFHxS, PFNA, HFPO-DA and PFBS, where our count is a few systems higher than the EPA's. For that reason this site does not publish its own Hazard Index counts.
What “above the limit” means here
The EPA states that UCMR 5 results do not indicate compliance or noncompliance with the limits. Compliance will be judged on a running annual average of quarterly results that each system reports to its state, and the limits do not apply until 2029. When this site says a system was above the limit, it means that a UCMR 5 sampling location averaged above it, nothing more.
Our national figure, 1,127 of the 10,128 systems with a full set of results, describes the systems that were tested. The EPA's figure of 7.8% (EPA, UCMR 5 Data Summary: July 2026, EPA 815-S-26-007, summary and the text under Table 4) is different on purpose: it weights the results to the number of water systems in the whole country, because small systems were only sampled. We quote the EPA's figure as the EPA's estimate and do not mix the two.
What we add, and how we check it
Pages about individual water systems also say what the system has done since it sampled, such as treatment built or wells taken out of service. That information comes from the system's own notices and reports, or from its state, with a link and the date we read it. A result above 40 ppt is shown as a number only after we have checked it against the individual samples and, where one exists, a source from the system itself. Where a single sample drives an average, the page shows both samples.
Percentages for a state are shown only when at least ten systems in that state have a full set of results.
Corrections
If a figure about your water system looks wrong, or is out of date, write to the address on the contact page with a link to the source. We check it against the EPA file and the system's own reports and correct the page, with a note of what changed and when.
Source: EPA UCMR 5, final data (files dated 2026-10-15), samples 2023–2026 (method).